摘要: 从人体舒适性及节能的角度出发,分析了陈列柜冷辐射对超市空调系统设计参数的影响,以此确定了合理的超市空调系统设计参数:夏季空调系统设计参数选择温度27℃,相对湿度60%;冬季空调系统设计参数选择温度不大于21℃,相对湿度30%.这两种状态下,节能效果和热舒适性较好.Abstract: From the points of comfort and energy saving,the display cabinet radiation should be taken into consideration when the parameter of HVAC system in supermarkets was set.And an experimental investigation was undertaken in test room.The results showed that:when 27℃,60% of humidity in summer and ≤21℃,30% of humidity in winter was set as the parameter of air conditioning in supermarket,the good energy saving and thermal comfort could be met.