HU Xiao-dong, ZHENG Pei-xuan, LI Jie and et al. Design and implementation of aging monitoring system of power supply products of DC power[J]. Journal of Light Industry, 2013, 28(6): 98-101. doi: 10.3969/j.issn.2095-476X.2013.06.023
Citation:
HU Xiao-dong, ZHENG Pei-xuan, LI Jie and et al. Design and implementation of aging monitoring system of power supply products of DC power[J]. Journal of Light Industry, 2013, 28(6): 98-101.
doi:
10.3969/j.issn.2095-476X.2013.06.023
Design and implementation of aging monitoring system of power supply products of DC power
-
Xuji Power Co., Ltd., State Grid Xuji Group, Xuchang 461000, China
-
Received Date:
2013-08-01
Available Online:
2013-11-15
-
Abstract
Taking the ATmega64 chip as the core of the circuit, the DC power supply aging monitoring system was designed. The system developed platform using industrial tablet computer as the main control machine, the functional unit of modular structure, driven by the RS845 interface bus and each functional unit to realize acquisition and monitoring of various parameters of the aging products. The practical application showed that the system had the advantages of good control effect, high reliability, flexible control.
-
-
References
-
Proportional views
-
-