YANG Cun-xiang, LIU Shu-bo and ZHANG Zhi-yan. Research on the diagnosis method of demagnetization fault of permanent magnet synchronous motor based on vector control[J]. Journal of Light Industry, 2017, 32(4): 58-65. doi: 10.3969/j.issn.2096-1553.2017.4.009
Citation:
YANG Cun-xiang, LIU Shu-bo and ZHANG Zhi-yan. Research on the diagnosis method of demagnetization fault of permanent magnet synchronous motor based on vector control[J]. Journal of Light Industry, 2017, 32(4): 58-65.
doi:
10.3969/j.issn.2096-1553.2017.4.009
Research on the diagnosis method of demagnetization fault of permanent magnet synchronous motor based on vector control
-
College of Electric and Information Engineering, Zhengzhou University of Light Industry, Zhengzhou 450002, China;
-
Isotope Institute Co., Ltd., He'nan Academy of Sciences, Zhengzhou 450015, China
-
Received Date:
2016-01-15
Accepted Date:
2016-09-15
Available Online:
2017-07-15
-
Abstract
Based on the fact that the simulation model of permanent magnet synchronous motor (PMSM) vector control system of demagnetization fault was built based on Matlab/Simulink platform,the diagnosis method of demagnetization fault of PMSM was presented using the control mode of id=0.The ratio of the electromagnetic torque and the stator current was used as the magnetic failure factor,the ratio of the electromagnetic torque and the stator current in normal operation was used as the threshold.If the magnetic failure factor was less than the threshold, the magnetic field could be judged demagnetization fault.And according to the magnitude of the magnetic failare factor and the threshold value, the magnetic field could be judged the severity of the loss.The simulation results verified the validity of the method.
-
-
References
-
[1]
王秀和.永磁电机[M].北京:中国电力出版社,2007.
-
[2]
王鑫,李伟力,程树康.永磁同步电动机发展展望[J].微电机,2007,40(5):69.
-
[3]
PRIETO M D, ESPINOSA A G, RUIZ J R R,et al.Feature extraction of demagnetization faults in permanent-magnet synchronous motors based on box-counting fractal dimension[J].IEEE Transactions on Industry Electronics,2011,58(5):923.
-
[4]
肖曦,张猛,李永东.永磁同步电机永磁体状况在线监测[J].中国电机工程学报,2007,27(24):43.
-
[5]
张志艳, 马宏忠, 陈诚,等.永磁电机失磁故障诊断方法综述[J].微电机, 2013, 46(3):77.
-
[6]
李三东,薛花,纪志成.基于Matlab永磁同步电机控制系统的仿真建模[J].江南大学学报(自然科学版),2004,3(2):115.
-
[7]
谢运祥,卢柱强.基于MATLAB/Simulink的永磁同步电机直接转矩控制仿真建模[J].华南理工大学学报(自然科学版),2004,32(1):19.
-
[8]
王沫然.Simulink 4建模及动态仿真[M].北京:电子工业出版社,2002.
-
[9]
龚云飞,富历新.基于MATLAB的永磁同步电机矢量仿真研究[J].微电机,2007,40(2):33.
-
[10]
崔胜民, 柏睿, 崔淑梅.PMSM在abc坐标下的建模及故障仿真[J].机械设计与制造,2011(7):178.
-
[11]
张红生, 胡炳娇.永磁同步电机电机本体数学模型在MATLAB中的仿真[J].自动化与仪器仪表,2012(2):134.
-
[12]
张金利,景占荣,张玉瑞,等.基于SVPWM的永磁同步电动机控制系统仿真与实验研究[J].微电机, 2008, 41(3):48.
-