水源热泵热水器在不同水源温度下的热力性能测试
Test on the thermal performance of the water-resource heat pump water heater under conditions of different inlet water temperatures
-
摘要: 对水源热泵热水器在蒸发侧不同的进水温度下的性能进行测试,结果表明:排气压力、排气温度和输入功率随着热水温度的升高而增加;制热功率和性能系数随着热水温度的升高而降低;系统的性能随着蒸发侧进水温度的升高而提高.当蒸发侧水温分别为12 ℃,15 ℃,30 ℃时,系统的制热功率分别为22.83 kW,25.95 kW,27.31 kW;系统的输入功率分别为5.30 kW,5.58 kW,5.84 kW;系统的制热系数分别为4.31,4.65,5.64.Abstract: An experiment was carried out on the performance of water-resource heat pump water heater under various inlet water temperature of evaporating side.The results showed that the discharge pressure, discharge temperature and power input were increased with hot water temperature; and the heating power and COP were decreased with hot water temperature. The coefficient of the system was increased with inlet water temperature on the evaporator side. The heating power of the system was 22.83 kW, 25.95 kW, 27.31 kW, the power consumption of the system was 5.30 kW,5.58 kW,5.84 kW, and the coefficient of the system was 4.31, 4.65 and 5.64 on conditions of evaporator inlet water temperature of 12 ℃, 15 ℃ and 30 ℃, respectively.
-
-
[1]
赵玉文.21世纪我国太阳能利用发展趋势[J].中国电力,2000,33(9):73.
-
[2]
HUANG J,CHYNG J P.Long term performance of solar assisted heat pump water heater[J].Renewable Energy,2003,29:633.
-
[3]
郭粉英,朱兴旺,仇富强.循环加热式空气源热泵热水器运行性能的试验研究[J].郑州轻工业学院学报,2009,24(4):71.
-
[4]
景洪."节能"是道坎更是机遇——兼谈空气源热泵器技术的前景[J].现代家电,2004(16):19.
-
[5]
孔祥雷,周培根,陈育平.一种回收排水热的新型热泵式热水器的设计[J].江苏科技大学学报(自然科学版),2009,23(5):407.
-
[6]
雷博,董建锴,沈德安,等.家用淋浴污水源热泵热水器系统实验[J].暖通空调,2014 (4):14.
-
[7]
仝高强,朱兴旺,苏宇贵,等.循环加热污水源热泵热水器运行性能的试验研究[J].流体机械,2014 (5):71.
-
[8]
王健敏,陈伟钦,林水荣,等.生活废热水余热利用的实验研究[J].制冷,2014 (3):30.
-
[9]
姜云涛,马一太,刘和成,等.高效换热的CO2水源热泵系统的实验研究[J].太阳能学报,2014,35(7):1125.
-
[1]
计量
- PDF下载量: 46
- 文章访问数: 939
- 引证文献数: 0