JOURNAL OF LIGHT INDUSTRY

CN 41-1437/TS  ISSN 2096-1553

Volume 33 Issue 4
July 2018
Article Contents
ZHANG Xiaojing, FU Haoqiang, ZHANG Nan, et al. Rapid start-up and stable operation of low-matrix Anammox filtration for treating low nitrogen sewage[J]. Journal of Light Industry, 2018, 33(4): 42-49. doi: 10.3969/j.issn.2096-1553.2018.04.006
Citation: ZHANG Xiaojing, FU Haoqiang, ZHANG Nan, et al. Rapid start-up and stable operation of low-matrix Anammox filtration for treating low nitrogen sewage[J]. Journal of Light Industry, 2018, 33(4): 42-49. doi: 10.3969/j.issn.2096-1553.2018.04.006 shu

Rapid start-up and stable operation of low-matrix Anammox filtration for treating low nitrogen sewage

  • Received Date: 2018-02-05
    Available Online: 2018-07-15
  • The ordinary activated sludge was inoculated into the volcanic rock biological filtration at 21.0~26.0℃. The parameters of the three experimental stages were adjusted to investigate the rapid start-up of the Anammox reactor and its stable operation strategy under low ammonia nitrogen conditions. The results showed that the first stage was high ammonia nitrogen and high alkalinity operation, the hydraulic retention time increased from 1.7 h to 6 h, the total nitrogen removal effect was not satisfactory, the reactor didn't start successfully; the second stage was high ammonia nitrogen and low alkalinity. The pre-filtration unit was operated and added to reduce the dissolved oxygen in the influent. On the 101st day, the effluent of the reactor showed obvious denitrification effect, the total nitrogen removal rate was about 40%, the reactor started successfully. The third stage was stable operation with low ammonia nitrogen and low alkalinity, the total nitrogen removal rate was up to 89%, the total effluent nitrogen was 11 mg/L, and the effluent nitrogen reached the first-class A effluent standard of the "Integrated Emission Standard for Pollutants in Urban Sewage Treatment Plants" (GB18918-2002). By controlling the lower DO value and the appropriate pH value, the rapid start-up and stable operation of the low-matrix Anammox reactor could be achieved within a certain temperature range.
  • 加载中
    1. [1]

      TERADA A,ZHOU S,HOSOMI M.Presence and detection of anaerobic ammonium-oxidizing (anammox)bacteria and appraisal of anammox process for high-strength nitrogenous wastewater treatment:a review[J].Clean Technologies and Environmental Policy,2011,13(6):759.

    2. [2]

      KARTAL B,KUENEN J G,VAN LOOSDRECHT M C M.Sewage treatment with anammox[J].Science,2010,328(5979):702.

    3. [3]

      鲍林林,赵建国,李晓凯,等.常温低基质厌氧氨氧化反应器启动及其稳定性[J].环境工程学报,2013,3(7):981.

    4. [4]

      张肖静,李冬,梁瑜海,等. MBR-CANON工艺处理生活污水的快速启动及群落变化[J].哈尔滨工业大学学报,2014,46(4):25.

    5. [5]

      张肖静,李冬,梁瑜海,等.氨氮浓度对CANON工艺性能及微生物特性的影响[J].中国环境科学,2014,34(7):1715.

    6. [6]

      李冬,苏庆岭,梁瑜海,等.CANON颗粒污泥高效脱氮及处理生活污水试验研究[J].哈尔滨工业大学学报,2015,47(8):79.

    7. [7]

      高伟楠,李冬,吴迪,等.厌氧氨氧化滤柱处理生活污水及稳定性[J].中国大学学报(自然科学报),2014,6(45):2112.

    8. [8]

      付丽霞,吴立波,张怡然,等.低含量氨氮污水厌氧氨氧化影响因素研究[J].水处理技术,2010,36(4):50.

    9. [9]

      张健,陈益明,邱凌峰,等.HRT与进水基质浓度对Anammox反应器效能影响研究[J].环境工程,2016,34(2):58.

    10. [10]

      陈重军,冯宇,汪瑶琪,等.厌氧氨氧化反应影响因素研究进展[J].生态环境学报,2016,25(2):346.

    11. [11]

      孙文汗,杨继刚.厌氧氨氧化的启动与影响因素[J].辽宁化工,2013,42(6):732.

    12. [12]

      孙艳波,周少奇,李秋生,等.氮素负荷及高温冲击对UASB-ANAMMOX反应器的运行影响[J].化工进展,2009,9(28):1672.

    13. [13]

      游少鸿,李小霞,解庆林,等.厌氧氨氧化影响因素实验研究[J].工业水处理,2009,10(29):27.

Article Metrics

Article views(1335) PDF downloads(38) Cited by()