基于双二阶广义积分器锁频环的基波正序分量检测方法
Detection method of fundamental positive sequence components based on double second-order generalized integrator frequency-locked loop
-
摘要: 针对电网电压三相不平衡问题,设计了双二阶广义积分器锁频环(DSOGI-FLL),利用DSOGI-FLL的角频率反馈代替双二阶广义积分器锁相环(DSOGI-PLL)的频率反馈,实现了对输入电压频率的自适应控制.在Matlab/Simulink平台对电压不对称跌落、谐波污染、相位突变、频率突变4种情况进行仿真,并与DSOGI-PLL进行性能对比,结果表明,DSOGI-FLL比DSOGI-PLL有更好的频率与相位追踪特性,尤其在相位突变和频率突变时效果更为明显.Abstract: In view of the problem of three-phase voltage unbalance, the double second-order generalized integrator frequency-locked loop (DSOGI-FLL) was designed.It used DSOGI-FLL angular frequency feedback instead of the second order generalized integrator phase-locked loop (DSOGI-PLL) frequency feedback, and realized the adaptive control of the input voltage frequency. Four conditions including asymmetric voltage drop, harmonic pollution, phase mutations, frequency mutations were simulated in Matlab/Simulink platform, and its performance was compared with DSOGI-PLL.The results showed that DSOGI-FLL had the better characteristics in tracking phase and frequency in all kinds of cases; especially so when the phase variation and frequency variation happened.
-
-
[1]
黄建明,吴春华,许富强.基于相序解耦谐振控制器的基波正序电压相位检测方法[J].电网技术,2013,37(3):667.
-
[2]
吴晓波,赵仁德,马帅.电网畸变条件下基于滑动平均自适应陷波滤波器的基波相位提取[J].电网技术,2013,37(12):3528.
-
[3]
王建勋,刘会金,韩丰收,等.用于谐波、间谐波在线监测的时频混合方法[J].电网技术,2012,36(10):229.
-
[4]
王颢雄,马伟明,肖飞,等.双dq变换软件锁相环的数学模型研究[J].电工技术学报,2011,26(7):237.
-
[5]
赵贵龙,祝龙记,曹玲玲,等.基于光伏并网低电压穿越的改进锁相环设计[J].低压电器,2014,6:28.
-
[6]
黄建明,吴春华,许富强.基于相序解耦谐振控制器的基波正序电压相位检测方法[J].电网技术,2013,37(3):667.
-
[7]
WIDROW B,GLOVER J R,MCCOOL J M,el at.Adaptive noise cancelling:principles and applications[J].Proceedings of the IEEE,1975,63(12):1692.
-
[8]
SAITOU M,MATSUI N,SIMIZU T.A control strategy of single-phase active filter using a novel d-q transformation[C]//38th IAS Annual Meeting on Conference Record of the Industry Applications Conference.Piscataway:IEEE,2003:1222.
-
[9]
薛尚青,蔡金锭.基于二阶广义积分器的基波正负序分量检测方法[J].电力自动化设备,2011,31(11):69.
-
[1]
计量
- PDF下载量: 115
- 文章访问数: 9883
- 引证文献数: 0