方支管-H型钢主管T型节点轴压性能数值分析
Numerical analysis of axial compression behavior for square hollow section brace-H section chord T-joints
-
摘要: 为研究方支管-H型钢主管平面T型节点的轴压性能,利用有限元软件ABAQUS,对方支管-H型钢主管平面T型节点进行模拟计算,以得到破坏模式和极限承载力.试验结果表明,破坏模式为支管根部屈曲破坏,极限承载力为242 kN,模拟结果和试验结果误差10.5%,有限元能够较好地模拟实验节点,工程中应适当增加支管壁厚以避免支管过快发生屈曲破坏.
-
关键词:
- 方支管-H型钢主管T型节点 /
- 轴压性能数值分析 /
- 破坏形态 /
- 极限承载力
Abstract: In order to study the axial compression behavior of square hollow section (SHS) brace-H section chord T-joint, a finite element model simulating the experiment on a SHS brace-H section chord T-joint was generated in order to obtain the failure mode and ultimate capacity using ABAQUS software. The results showed that the failure mode is brace local buckling and the ultimate capacity is 242 kN. The error of experiment compare with simulation is 10.5%. The brace was buckling since the square hollow section is a thin-walled component relative to H section chord. The finite element model is quite similar to the experimental one, and the wall thickness of brace should be thicken to avoid buckling. -
-
[1]
曹国峰,姚念亮.T形焊接方管内加劲节点轴向力下的承载力[J].同济大学学报:自然科学版,2007,35(10):1331.
-
[2]
吴文奇,吴耀华,卢晋福.考虑截面圆角效应的T型方管相贯节点静力承载力研究[J].钢结构,2005,20(78):21.
-
[3]
Cao J J, Packer J A, Yong G J.Yield line analysis of RHS connections with axial loads[J].Journal of Constructional Steel Research,1998,48:1.
-
[4]
Zhao X L.Deformation limit and ultimate strength of welded T-joints in cold-formed RHS sections[J].Journal of Constructional Steel Research,2000,53:149.
-
[5]
陈以一,张梁,王拓.无加劲冷成型方钢管-H形钢梁翼缘板焊接节点受拉性能试验研究[J].建筑结构学报,2011,32(5):24.
-
[6]
张梁,陈以一,王拓.无加劲冷成型方钢管-H形钢梁翼缘板焊接节点管壁变形初始刚度分析[J].建筑结构学报,2011,32(5):32.
-
[7]
DD ENV 1993-1-1.CEN:Eurocode 3:Design of steel structures, Part 1-8 design of joints[S].
-
[1]
计量
- PDF下载量: 26
- 文章访问数: 775