HUANG Si-fang, SONG Ze-ya, DUAN Qiang and et al. The short-circuit current non-periodic components and its application in relay protection and control[J]. Journal of Light Industry, 2015, 30(2): 88-92. doi: 10.3969/j.issn.2095-476X.2015.02.019
Citation:
HUANG Si-fang, SONG Ze-ya, DUAN Qiang and et al. The short-circuit current non-periodic components and its application in relay protection and control[J]. Journal of Light Industry, 2015, 30(2): 88-92.
doi:
10.3969/j.issn.2095-476X.2015.02.019
The short-circuit current non-periodic components and its application in relay protection and control
-
College of Electric and Information Engineering, Zhengzhou University of Light Industry, Zhengzhou 450002, China;
-
Yicheng District Highway Administration Bureau, Zhumadian 463000, China
-
Received Date:
2014-11-19
Available Online:
2015-03-15
-
Abstract
Aiming at how to accurately determine the short circuit fault in power system in order to improve the reliability and sensitivity of the relay protection of power system, a method which used short-circuit current in a non-periodic component as a criterion in short-circuit fault was proposed. Using Matlab to extract short-circuit current of the non-periodic component,was then applied the features of the non-periodic component in the short circuit current to the relay protection of power system. The test run results showed that the directional differential protection of non-periodic components was not affected by the influence of line to ground capacitance. Either as a sole major protection, or as a part of the combined protections, it can always accurately identify the short fault of electric system. However, non-periodic components are transient signals with short existence, therefore a signal maintainer is needed during operation.
-
-
References
-
Proportional views
-
-